PANEL KAPASITOR BANK 600 kVAR
panel kapasitor bank 600 kvar/panel kapasitor bank/kapasitor bank/jual panel kapasitor bank 600 kvar/jual panel kapasitor bank/jual panel kapasitor bank 600 kvar murah/harga panel kapasitor bank/harga panel kapasitor bank 600 kvar/kapasitor bank 600 kvar/jual panel kapasitor bank 600 kvar/harga panel capacitor bank 600 kvar/panel capacitor bank 600 kvar/jual panel capacitor bank 600 kvar
Rp198.105.000,00
MINTA PENAWARAN
BAGIKAN :
Share on facebook
Share on twitter
Share on linkedin
Share on whatsapp
Share on email
Share on pinterest
Share on google
Product Data Sheet CAPACITOR BANK 600 kVAR | |
---|---|
Characteristic | Auto & Manual |
400 Volt, 50 Hz | |
Main | |
Network rated voltage | 400 VAC 50 Hz |
415 VAC 50 Hz | |
Reactive Power Rating | 600 kVAR |
Operating Mode | Automatic & Manual |
Device Short Name | KVAR Automanual |
Product Name | Capacitor Bank |
Complementary | |
Network Pollution Level | Low polluted |
Harmonic polution rate | 15 - 25 % |
(THDU) total Harmonic Distortion of Voltage | |
Power per Step | 12 Step |
Step Compotition | 3 Phase 50 kVAR 450 Volt |
Location of Connection | Bottom |
Controller Type | JKF8 Series |
Capacitor Technology | Dry Type Filled with Dry Flame-Reterdant Material Internally |
Capacitor Protection | Over pressure Device & Disconnecting Fuse |
Poles Description | 3 Poles |
Capacitance Error | - 5% to 10 % |
Rated Insulation Voltage | 690 Volt |
Rated Impulse Withstand Voltage | 8 kV |
Maximum Permisible Voltage | 1.1 x Un (8 Hours over 24 hours) |
Maximum Permanent Current | Capacitor : 1.3 x In at 450 Volt |
Main Incomer Protection | Without Protection |
Rated Short Circuit-time Withstand current | 18 kA at 1 s |
Step Protection type | Overload : Harmonic Control from JKF8 |
Short Circuit : Non Fuse Breaker | |
Accessibility for operation | Front Access |
Colour | Light Grey (RAL 7032) |
Dimension | |
- Height (mm) | 2000 mm |
- Width (mm) | 600 + 800 mm |
- Depth (mm) | 600 mm |
Provided equipment | Auxiliary Transformer |
Internal Voltage Transformer | 400 / 230 Volt 500 VA |
Function available | Genset Shedding Contact |
Alarm Contact | |
Environment | |
Standard | IEC 61439-1 |
Mounting Location | Indoor |
IP Degree Protection | Environment : IP 31 |
IK Degree Protection | IK10 |
Relative Humidity | 0 … 95 % |
Operation Altitude | <= 2000 meters |
Ambient Air Temperature for operation | -5 … 45˚C |
Average Ambient Air Temperature for Operation | 35 ˚ C (Annual) |
45 ˚ C (Over 24 hours) |
Bill Of Quantity | |
---|---|
Characteristic | Auto & Manual |
400 Volt, 50 Hz | |
Main Circuit Breaker for Incoming | Load Break Switch |
3P1000A 400V | |
Step Design of Capacitor Bank | 12 Step |
Short Circuit Protection for Capacitor | Mould Case Circuit Breaker |
3P 100A 20 kA 400 Volt | |
Last Step Protection of Capacitor | Contactor |
Capacitor Steps | 50 kVAR |
Power Factor Regulator | JKB Series |
12 Step | |
Capacitor Bank Mode | Auto - 0 - Manual |
Indication Capacitor Operation | Pilot Lamp Diammeter 22 Red Colour |
Operation Manual Mode | Push Button Diameter 22, Red For ON and Green for OFF |
Door Mounting | |
Door Mounting | Power Factor Regulator |
Cosphi Meter | |
Lamp Indication of Step Power Capacitor & Mode Capacitor | |
Enclosure | |
Enclosure Standard | NEMA 1 |
Enclosure Constructed | Metal Enclose Form Sparation 1 |
Ventilating System | Cooling Air Intake with Grill and Out Let with Exhaust Fan |
Heating | Anti Condensation Heater 50 Watt |
Access | Buttom Entry |
Dimension | |
Width (mm) | 600 + 800 |
Height (mm) | 2000 |
Depth (mm) | 600 |
Material | Mild Steel Plate 1,8 mm |
Finishing | Painting Powder Coating RAL 7032 |
Conductor | |
Main Conductor & Main Busbar | Cooper Busbar |
2//10x80 | |
Branch Conductor | Cooper Busbar / Cable as per Load Capacity |
Phase Indication Busbar / Cable | Heat Shrink Tube Insulated 1 kV / Rubber Vinyl |
Wiring | |
Control Wiring | Cable 1,5 mm² |
Current Transformer Wiring | Cable 2,5 mm² |
Potential Transformer Wiring | Cable 2,5 mm² |
PANEL KAPASITOR BANK 600 KVAR
Product Data Sheet CAPACITOR BANK 600 kVAR | |
---|---|
Characteristic | Auto & Manual |
400 Volt, 50 Hz | |
Main | |
Network rated voltage | 400 VAC 50 Hz |
415 VAC 50 Hz | |
Reactive Power Rating | 600 kVAR |
Operating Mode | Automatic & Manual |
Device Short Name | KVAR Automanual |
Product Name | Capacitor Bank |
Complementary | |
Network Pollution Level | Low polluted |
Harmonic polution rate | 15 – 25 % |
(THDU) total Harmonic Distortion of Voltage | |
Power per Step | 12 Step |
Step Compotition | 3 Phase 50 kVAR 450 Volt |
Location of Connection | Bottom |
Controller Type | JKF8 Series |
Capacitor Technology | Dry Type Filled with Dry Flame-Reterdant Material Internally |
Capacitor Protection | Over pressure Device & Disconnecting Fuse |
Poles Description | 3 Poles |
Capacitance Error | – 5% to 10 % |
Rated Insulation Voltage | 690 Volt |
Rated Impulse Withstand Voltage | 8 kV |
Maximum Permisible Voltage | 1.1 x Un (8 Hours over 24 hours) |
Maximum Permanent Current | Capacitor : 1.3 x In at 450 Volt |
Main Incomer Protection | Without Protection |
Rated Short Circuit-time Withstand current | 18 kA at 1 s |
Step Protection type | Overload : Harmonic Control from JKF8 |
Short Circuit : Non Fuse Breaker | |
Accessibility for operation | Front Access |
Colour | Light Grey (RAL 7032) |
Dimension | |
– Height (mm) | 2000 mm |
– Width (mm) | 600 + 800 mm |
– Depth (mm) | 600 mm |
Provided equipment | Auxiliary Transformer |
Internal Voltage Transformer | 400 / 230 Volt 500 VA |
Function available | Genset Shedding Contact |
Alarm Contact | |
Environment | |
Standard | IEC 61439-1 |
Mounting Location | Indoor |
IP Degree Protection | Environment : IP 31 |
IK Degree Protection | IK10 |
Relative Humidity | 0 … 95 % |
Operation Altitude | <= 2000 meters |
Ambient Air Temperature for operation | -5 … 45˚C |
Average Ambient Air Temperature for Operation | 35 ˚ C (Annual) |
45 ˚ C (Over 24 hours) |
Bill Of Quantity | |
---|---|
Characteristic | Auto & Manual |
400 Volt, 50 Hz | |
Main Circuit Breaker for Incoming | Load Break Switch |
3P1000A 400V | |
Step Design of Capacitor Bank | 12 Step |
Short Circuit Protection for Capacitor | Mould Case Circuit Breaker |
3P 100A 20 kA 400 Volt | |
Last Step Protection of Capacitor | Contactor |
Capacitor Steps | 50 kVAR |
Power Factor Regulator | JKB Series |
12 Step | |
Capacitor Bank Mode | Auto – 0 – Manual |
Indication Capacitor Operation | Pilot Lamp Diammeter 22 Red Colour |
Operation Manual Mode | Push Button Diameter 22, Red For ON and Green for OFF |
Door Mounting | |
Door Mounting | Power Factor Regulator |
Cosphi Meter | |
Lamp Indication of Step Power Capacitor & Mode Capacitor | |
Enclosure | |
Enclosure Standard | NEMA 1 |
Enclosure Constructed | Metal Enclose Form Sparation 1 |
Ventilating System | Cooling Air Intake with Grill and Out Let with Exhaust Fan |
Heating | Anti Condensation Heater 50 Watt |
Access | Buttom Entry |
Dimension | |
Width (mm) | 600 + 800 |
Height (mm) | 2000 |
Depth (mm) | 600 |
Material | Mild Steel Plate 1,8 mm |
Finishing | Painting Powder Coating RAL 7032 |
Conductor | |
Main Conductor & Main Busbar | Cooper Busbar |
2//10×80 | |
Branch Conductor | Cooper Busbar / Cable as per Load Capacity |
Phase Indication Busbar / Cable | Heat Shrink Tube Insulated 1 kV / Rubber Vinyl |
Wiring | |
Control Wiring | Cable 1,5 mm² |
Current Transformer Wiring | Cable 2,5 mm² |
Potential Transformer Wiring | Cable 2,5 mm² |